Thyssenkrupp Levant Stair Lift Installation Manual Full !!link!!

Ensure the staircase is at least 28 inches (711 mm) wide to allow the carriage and user to clear the walls.

This strict policy exists for several critical reasons:

Splice plates and hardware to connect rail sections.

should ideally be installed by a certified ThyssenKrupp technician. Improper installation can void the warranty. thyssenkrupp levant stair lift installation manual full

A dedicated 110V AC, 60Hz grounded outlet must be within reach of the trailing cable or charging transformer. Required Tools Digital spirit level (minimum 24 inches)

Install the support legs or feet that attach the rail to the steps. Ensure the rail is level and properly spaced along the flight of stairs.

If your rail comes in two pieces, insert the steel joint pins into the internal chambers of the lower rail. Slide the upper rail section onto the joint pins. Ensure the staircase is at least 28 inches

Secure the brackets to the stairs using the provided heavy-duty wood lag screws or concrete anchors. Do not fully tighten them yet; leave room for minor adjustments. Step 4: Loading the Carriage onto the Rail

Metric socket set, Allen keys (4mm–8mm), spirit level, drill with masonry/wood bits, and a multimeter.

Tighten the joint bolts securely using the specified hex wrench. Step 2: Attaching the Rail Brackets (Feet) Improper installation can void the warranty

The manual mandates that the technician complete:

Carefully unpack the components and verify them against the packing list in the manual: Straight rail(s). Carriage: The main motor unit. Chair Assembly: Seat, footrest, and armrests. Battery Charger/Transformer. Installation Hardware. 3. Step-by-Step Installation Process A. Installing the Rail

Distribute the mounting brackets evenly along the rail. Use at least one bracket per three steps, placing one bracket immediately below the top joint and one just above the bottom landing.